Skip to main content

Greenbyte Documentation

Potential Power Reference Inverters

This signal calculates potential power based on the average yield of reference inverters for this inverter.

Technology

Solar

Remarks

The reference inverters used will be all inverters configured as references for this inverter. If no reference inverters are configured, all other inverters in the same site will be used instead.

Required metadata fields:

  • DC Capacity (kWp) (Inverter metadata 7)

Optional metadata fields:

  • Availability Irradiance Cut-In (W/m2) (Inverter metadata 8)

Equation
Potential_Power_Reference_Inverters_-_Equation.png

Where:

Pp

is the Potential power (reference inverters)

Cut-inIA

is the Availability Irradiance Cut-In (W/m2) (Inverter metadata 8)

I

is the Solar Irradiance Reference for each time step

CDC

is the DC capacity (kWp) (Inverter metadata 7)

Iref

the set of references inverters for this inverter

n

is the number of reference inverters

Yi

is the Yield DC value for inverter i

Inputs
Potential_Power_Reference_Inverters_-_Inputs.png
Usage Example

In this example, you can see the Potential Power Reference Inverters signal is shown with the Power AC signal in the Data Studio.