This calculation makes it possible to estimate the power for an inverter, given forecast values for its Performance Ratio.

Technology

Solar

Remarks

The signal is not allowed to have negative values. They are instead replaced with 0.

Required metadata fields:

  • DC Capacity (kWp), set per inverter

Optional metadata fields:

  • Availability Irradiance Cut-In (W/m2), set per inverter

  • Performance Irradiance Cut-In (W/m2), set per inverter

Note

For more information about how the Irradiance cut-in will be applied, see Common Solar Concepts.

Equation
Potential_Power_Performance_Ratio_Forecast_-_Equation.png

Where:

Pp+

is the Potential Power PR Forecast, clamped to the positive part

PRforecast

is the Performance ratio forecasts

CDC

is the DC Capacity (kWp) (Inverter metadata 7)

ISTC

is the Irradiance used under Standard Test Conditions (1000 W/m2)

I

is Solar Irradiance Reference

Cut-inIP

is the Performance Irradiance Cut-In (W/m2) (Device metadata 16)

Cut-inIA

is the Availability Irradiance Cut-In (W/m2) (Device metadata 15)

Inputs
Potential_Power_Performance_Ratio_Forecast_-_Inputs.png
Usage Example

Plotted in an Average over time widget on the Monitor / Portfolio page.

Potential_Power_Performance_Ratio_Forecast_-_Usage_Example.png