Potential Power Irradiance Only

This signal calculates the potential power given Irradiance and Capacity. Irradiance cut-in and degradation are also applied if the corresponding metadata values are available.

Technology

Solar

Remarks

Required metadata fields:

  • DC Capacity (kWp) (Inverter metadata 7)

Optional metadata fields:

  • Availability Irradiance Cut-In (W/m2) (Inverter metadata 8)

  • Degradation Factor (Site metadata 10) - degradation skipped if missing

  • Commissioning Date (Inverter metadata 23) - degradation skipped if missing

Equation

For each time step, it is calculated like this:

Potential_Power_Irradiance_Only_-_Equation.png

Where:

Pp+

is the Potential Power Irradiance Only, clamped to the positive part

I

is the Solar Irradiance Reference for each time step

Cut-inIA

is the Availability Irradiance Cut-In (W/m2) (Inverter metadata 8) and applied to the irradiance if it exists.

ISTC

is irradiance used under Standard Test Conditions (1000 W/m2)

CDC

is DC Capacity (kWp) (Inverter metadata 7)

degrade

If the degradation factor and Commissioning Date metadata values are available, the degradation will be applied to the resulting potential power.

Inputs
Potential_Power_Irradiance_Only_-_Inputs.png
Usage Example

This is an example of the signal with cut-in applied at 100 W/m2.

Potential_Power_Irradiance_Only_-_Usage_Example.png