Performance Ratio (IEC Module Temp. Corrected)

Temperature-corrected performance ratio according to IEC-61724-1.

Technology

Solar

Remarks

This calculation requires Solar Irradiance Reference, Energy, and Module temperature in order to be calculated.

Required metadata field:

  • DC Capacity (kW) (Inverter metadata 7)

Optional metadata fields:

  • Performance Irradiance Cut-In (W/m2) (Inverter metadata 13) - if missing a default of 20W/m2 will be used.

  • Cell Reference Temperature (°C) (Inverter metadata 35) - if missing a default of 25°C will be used.

  • Power Temperature Coefficient (%/°C) (Site metadata 27) - if missing a default of -0.3% will be used.

Note

This signal is resolution-dependent.

Equation
Performance_Ratio__IEC_Module_Temp__Corrected__-_Equation.png

Where:

PR

is the Performance Ratio (IEC)

Epotential

is the potential energy production

Eactual

is the actual energy production

I

is Solar Irradiance Reference for each time step

cut-inIP

is the Performance Irradiance Cut-In (W/m2) (Inverter metadata 13), with a fallback to 20 W/m2

ISTC

is irradiance used under Standard Test Conditions (1000 W/m2)

CDC

is the DC Capacity (kW) (Inverter metadata 7)

K

is the Power Temperature Coefficient (%/°C) (Site metadata 27) with a fallback to -0.3%/°C

Tmodule

is the average of available module temperature signals

T0

is the Cell Reference Temperature (°C) (Inverter metadata 35), with a fallback to 25°C

E

is the Energy or Power with Fallback

T

is the device resolution in hours

Inputs
Performance_Ratio__IEC_Module_Temp__Corrected__-_Inputs.png
Usage Example

This section will be updated later.