Skip to main content

Greenbyte Documentation

Lost Production Residual (Inverter)

Lost Production Residual is the difference between the Energy Theoretical and the sum of Energy Actual and all known losses. This signal might consist of both a positive part of uncategorized losses, as well as a negative part of lost production that for some reason is covered by more than one Lost Production category.

Lost Production Residual = Energy Theoretical - ( Energy Actual + LP to Performance + LP to Curtailment + LP to Downtime )

Technology

Solar

Remarks

Any signal value that does not exist for some timestep, is counted as 0 kWh.

Equation
Lost_Production_Residual__Inverter__-_Equation.png

Where:

LPr

is the Lost Production Residual

Etheoretical

is the Energy Theoretical (Inverter)

Eactual

is the Energy with fallback

LPp

is the Lost Production to Performance (Inverter)

LPc

is the Lost Production to Curtailment (Total)

LPd

is the Lost Production to Downtime (Inverter)

Inputs
Lost_Production_Residual__Inverter__-_Inputs.png
Usage Example

This example shows Lost Production Residual with its dependent signals.

Lost_Production_Residual__Inverter__-_Usage_Example.png