This signal determines when all inverters/turbines mapped to the meter can be considered “offline”: that is when there is no production at all. If all devices are mapped to this meter, it gives information about the status of the entire site. This is useful for the Production-Based Availability (Inverter Normalized) KPI which defines “downtime” as when the entire site is down, rather than individual inverters.

Technologies

Solar and Wind

Remarks

This signal is available for all Energy meters (Grid meters or Production meters).

It is used in Lost Production to Performance (Inverter Normalized) and Lost Production to Downtime (Inverter Normalized).

Equation
Energy_Meter-based_Availability_-_Equation.png

Where:

Aenergymeter

is the Energy meter-based availability

EG

is the Grid meter Energy export

EGMS

is the GMS Energy Export (Production meter)

Inputs
Energy_Meter-based_Availability_-_Inputs.png
Usage Example

In this example, we have plotted in Data Studio for 1 day (sunrise to sunset). As you can see, the value is either 100% (online) or 0% (offline).